image accueil du logo de la rubrique
Mars Microphone 2020

Mars Microphone 2020 webpage.

Vous êtes ici : Mars Microphone 2020 » Microphone Qualification Tests » A brief comparison between normal conditions, 5 mbar and -40°C

A brief comparison between normal conditions, 5 mbar and -40°C

D 11 mars 2015    


Here is a comparison between tests under normal conditions, 5 mbar and -40°C.
It shows that :

  • a lower pressure decreases the sound power received by the microphone while temperature has no effect on it
  • the microphone is well qualified at least above 2000 Hz in extreme conditions

Dans la même rubrique


Test with a 5 mbar pressure Introduction We made the first tests at IRAP, in a vacuum chamber. The goal of these tests was to qualify the (...)



Monday 9 February 2015
Test at -40°C As we had already tested the microphone at low pressure, the objective of this test was to determine the frequency (...)